Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/30891
Title: | A systematic review: Cost-effectiveness of continuous glucose monitoring compared to self-monitoring of blood glucose in type 1 diabetes. | Austin Authors: | Jiao, Yuxin;Lin, Rose;Hua, Xinyang;Churilov, Leonid ;Gaca, Michele ;James, Steven;Clarke, Philip M;O'Neal, David;Ekinci, Elif I | Affiliation: | Austin Health Centre for Health Policy, Melbourne School of Population and Global Health, University of Melbourne, Carlton, Victoria, Australia.. Melbourne Medical School, The University of Melbourne, Parkville, Victoria, Australia.. Austin Health Sciences Library School of Nursing, Midwifery and Paramedicine, University of the Sunshine Coast, Petrie, Queensland, Australia.. Health Economics Research Centre, Nuffield Department of Population Health, University of Oxford, Oxford, UK.. Department of Medicine, St Vincent's Hospital Melbourne, Melbourne Medical School, The University of Melbourne, Parkville, Victoria, Australia.. General Medicine |
Issue Date: | 16-Sep-2022 | Date: | 2022 | Publication information: | Endocrinology, Diabetes & Metabolism 2022: e369 | Abstract: | Continuous glucose monitoring (CGM) is rapidly becoming a vital tool in the management of type 1 diabetes. Its use has been shown to improve glycaemic management and reduce the risk of hypoglycaemic events. The cost of CGM remains a barrier to its widespread application. We aimed to identify and synthesize evidence about the cost-effectiveness of utilizing CGM in patients with type 1 diabetes. Studies were identified from MEDLINE, Embase and Cochrane Library from January 2010 to February 2022. Those that assessed the cost-effectiveness of CGM compared to self-monitored blood glucose (SMBG) in patients with type 1 diabetes and reported lifetime incremental cost-effectiveness ratio (ICER) were included. Studies on critically ill or pregnant patients were excluded. Nineteen studies were identified. Most studies compared continuous subcutaneous insulin infusion and SMBG to a sensor-augmented pump (SAP). The estimated ICER range was [$18,734-$99,941] and the quality-adjusted life year (QALY) gain range was [0.76-2.99]. Use in patients with suboptimal management or greater hypoglycaemic risk revealed more homogenous results and lower ICERs. Limited studies assessed CGM in the context of multiple daily injections (MDI) (n = 4), MDI and SMBG versus SAP (n = 2) and three studies included hybrid closed-loop systems. Most studies (n = 17) concluded that CGM is a cost-effective tool. This systematic review suggests that CGM appears to be a cost-effective tool for individuals with type 1 diabetes. Cost-effectiveness is driven by reducing short- and long-term complications. Use in patients with suboptimal management or at risk of severe hypoglycaemia is most cost-effective. | URI: | https://ahro.austin.org.au/austinjspui/handle/1/30891 | DOI: | 10.1002/edm2.369 | ORCID: | https://orcid.org/0000-0001-7580-3623 https://orcid.org/0000-0001-7350-3299 https://orcid.org/0000-0002-3928-9206 https://orcid.org/0000-0003-2372-395X |
Journal: | Endocrinology, Diabetes & Metabolism | PubMed URL: | 36112608 | Type: | Journal Article | Subjects: | continuous glucose monitoring cost-analysis cost-effectiveness health economics self-monitoring blood glucose type 1 diabetes |
Appears in Collections: | Journal articles |
Show full item record
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.