Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/22998
Title: Robot-assisted ipsilateral ureteroureterostomy in a duplex system utilizing intraoperative flexible ureteroscopy.
Austin Authors: O'Connor, Ellen ;Teh, Jiasian ;Lawrentschuk, Nathan
Affiliation: Division of Cancer Surgery, Peter MacCallum Cancer Centre, Melbourne, Australia
Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, Victoria, Australia
Issue Date: Jul-2020
Date: 2020-04-02
Publication information: Urology case reports 2020; 31: 101158
Abstract: Iatrogenic injury to the ureter during pelvic surgery is an uncommon but well-documented complication. Accurate identification of the ureter during pelvic surgery is made far more complex in the presence of a duplex or ectopic system, an anomaly occurring in up to 2% of the population. In this article we present a technique for robot-assisted ipsilateral ureteroureterostomy for treatment of iatrogenic injury of a lower pole moiety ureter in a complete duplex system.
URI: https://ahro.austin.org.au/austinjspui/handle/1/22998
DOI: 10.1016/j.eucr.2020.101158
ORCID: 0000-0002-7882-5155
0000-0001-8553-5618
Journal: Urology case reports
PubMed URL: 32280594
ISSN: 2214-4420
Type: Journal Article
Subjects: Iatrogenic injury
Robotic surgical procedures
Surgical anastomosis
Ureter
Urogenital abnormalities
Appears in Collections:Journal articles

Show full item record

Page view(s)

18
checked on Mar 28, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.