Title: Robot-assisted ipsilateral ureteroureterostomy in a duplex system utilizing intraoperative flexible ureteroscopy.
Austin Authors: O'Connor, Ellen ;Teh, Jiasian ;Lawrentschuk, Nathan
Affiliation: Division of Cancer Surgery, Peter MacCallum Cancer Centre, Melbourne, Australia
Department of Surgery, Austin Health, The University of Melbourne, Heidelberg, Victoria, Australia
Issue Date: Jul-2020
Date: 2020-04-02
Publication information: Urology case reports 2020; 31: 101158
Abstract: Iatrogenic injury to the ureter during pelvic surgery is an uncommon but well-documented complication. Accurate identification of the ureter during pelvic surgery is made far more complex in the presence of a duplex or ectopic system, an anomaly occurring in up to 2% of the population. In this article we present a technique for robot-assisted ipsilateral ureteroureterostomy for treatment of iatrogenic injury of a lower pole moiety ureter in a complete duplex system.
URI: https://ahro.austin.org.au/austinjspui/handle/1/22998
DOI: 10.1016/j.eucr.2020.101158
ORCID: 0000-0002-7882-5155
0000-0001-8553-5618
Journal: Urology case reports
PubMed URL: 32280594
ISSN: 2214-4420
Type: Journal Article
Subjects: Iatrogenic injury
Robotic surgical procedures
Surgical anastomosis
Ureter
Urogenital abnormalities