Title: | The effect of the AN69 ST100 versus oXiris® membrane on filter life during CRRT for non-anticoagulated liver failure patients. | Austin Authors: | Naorungroj, Thummaporn ;Baldwin, Ian C ;Eastwood, Glenn M ;Bellomo, Rinaldo | Affiliation: | Intensive Care Division of Intensive Care, Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand Data Analytics Research and Evaluation (DARE) Centre |
Issue Date: | 9-Mar-2023 | Date: | 2023 | Publication information: | The International journal of artificial organs 2023; 46(4) | Abstract: | In patients with liver failure, continuous renal replacement therapy (CRRT) without anticoagulation may be necessary. A new heparin coated membrane (oXiris®) may prolong circuit life in this setting. In liver failure patients not receiving anticoagulation, to compare CRRT circuit life with the oXiris® versus the AN69 ST100 (usual care) membrane. Randomized single cross-over trial. We studied 20 patients and 39 circuits. Twenty-five treatments used femoral and 14 internal jugular access catheters. Median circuit life was 21 h (IQR: 8.25-35.5) with the AN69 versus 16.0 h (14-25) with the oXiris® membrane (p = 0.36). Median first circuit duration was 14 (11.25-23) h for the AN69 ST100 versus 16 (8 -26) for the oXiris® membrane. There was also no difference between the AN69 ST100 or oXiris® membrane circuits using femoral access at 13 (8 -22.5) versus 15.5 (12.5-21.5) h (p = 0.57) or internal jugular access at 28 (13-47) versus 23 (21-29) h (p = 0.79), respectively. The oXiris® heparin-grafted membrane does not appear to prolong circuit life in liver failure patients receiving CRRT without anticoagulation. | URI: | https://ahro.austin.org.au/austinjspui/handle/1/32311 | DOI: | 10.1177/03913988231155253 | ORCID: | 0000-0001-6562-4891 |
Journal: | The International Journal of Artificial Organs | Start page: | 3913988231155253 | PubMed URL: | 36895128 | ISSN: | 1724-6040 | Type: | Journal Article | Subjects: | Continuous renal replacement therapy Intensive Care Unit apheresis & detoxification techniques artificial kidney circuit life clotting hemofiltration liver failure oXiris® |
Appears in Collections: | Journal articles |
Show full item record
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.