Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/30686
Title: β-amyloid PET harmonisation across longitudinal studies: Application to AIBL, ADNI and OASIS3.
Austin Authors: Bourgeat, Pierrick;Doré, Vincent ;Burnham, Samantha C;Benzinger, Tammie;Tosun, Duygu;Li, Shenpeng;Goyal, Manu;LaMontagne, Pamela;Jin, Liang;Rowe, Christopher C ;Weiner, Michael W;Morris, John C;Masters, Colin L ;Fripp, Jurgen;Villemagne, Victor L 
Affiliation: Department of Psychiatry, The University of Pittsburgh, Pittsburgh, PA, USA..
Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA..
CSIRO Health and Biosecurity, Brisbane, Australia
The Florey Institute of Neuroscience and Mental Health
Molecular Imaging and Therapy
Knight Alzheimer Disease Research Center, St. Louis, MO, USA..
San Francisco Veterans Affairs Medical Center, San Francisco, CA, USA..
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, USA..
Washington University in St. Louis, St. Louis, MO, USA..
Issue Date: 30-Jul-2022
Date: 2022
Publication information: NeuroImage 2022; 262: 119527
Abstract: The Centiloid scale was developed to harmonise the quantification of β-amyloid (Aβ) PET images across tracers, scanners, and processing pipelines. However, several groups have reported differences across tracers and scanners even after centiloid conversion. In this study, we aim to evaluate the impact of different pre and post-processing harmonisation steps on the robustness of longitudinal Centiloid data across three large international cohort studies. All Aβ PET data in AIBL (N=3315), ADNI (N=3442) and OASIS3 (N=1398) were quantified using the MRI-based Centiloid standard SPM pipeline and the PET-only pipeline CapAIBL. SUVR were converted into Centiloids using each tracer's respective transform. Global Aβ burden from pre-defined target cortical regions in Centiloid units were quantified for both raw PET scans and PET scans smoothed to a uniform 8mm full width half maximum (FWHM) effective smoothness. For Florbetapir, we assessed the performance of using both the standard Whole Cerebellum (WCb) and a composite white matter (WM)+WCb reference region. Additionally, our recently proposed quantification based on Non-negative Matrix Factorisation (NMF) was applied to all spatially and SUVR normalised images. Correlation with clinical severity measured by the Mini-Mental State Examination (MMSE) and effect size, as well as tracer agreement in 11C-PiB-18F-Florbetapir pairs and longitudinal consistency were evaluated. The smoothing to a uniform resolution partially reduced longitudinal variability, but did not improve inter-tracer agreement, effect size or correlation with MMSE. Using a Composite reference region for 18F-Florbetapir improved inter-tracer agreement, effect size, correlation with MMSE, and longitudinal consistency. The best results were however obtained when using the NMF method which outperformed all other quantification approaches in all metrics used. FWHM smoothing has limited impact on longitudinal consistency or outliers. A Composite reference region including subcortical WM should be used for computing both cross-sectional and longitudinal Florbetapir Centiloid. NMF improves Centiloid quantification on all metrics examined.
URI: https://ahro.austin.org.au/austinjspui/handle/1/30686
DOI: 10.1016/j.neuroimage.2022.119527
ORCID: 0000-0003-1695-3300
0000-0002-8051-0558
0000-0003-3910-2453
0000-0003-3072-7940
0000-0002-5832-9875
Journal: NeuroImage
PubMed URL: 35917917
PubMed URL: https://pubmed.ncbi.nlm.nih.gov/35917917/
Type: Journal Article
Subjects: Amyloid PET
Centiloid
Harmonisation
Appears in Collections:Journal articles

Show full item record

Page view(s)

66
checked on Dec 23, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.