Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/28828
Title: | Neutron and photon out-of-field doses at cardiac implantable electronic device (CIED) depths. | Austin Authors: | Aslian, Hossein;Severgnini, Mara;Khaledi, Navid;Ren Kaiser, Stefano;Delana, Anna;Vidimari, Rossella;de Denaro, Mario;Longo, Francesco | Affiliation: | Olivia Newton-John Cancer Wellness and Research Centre Department of Physics, University of Trieste, Trieste, Italy Department of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy Department of Physics, Faculty of Science, Ryerson University, Toronto, ON, Canada Department of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy Department of Medical Physics, S. Chiara Hospital, APSS, Trento, Italy Department of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy Department of Physics, University of Trieste, Trieste, Italy; Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste, Italy |
Issue Date: | Oct-2021 | Date: | 2021-08-15 | Publication information: | Applied radiation and isotopes 2021; 176: 109895 | Abstract: | The accuracy of an out-of-field dose from an Elekta Synergy accelerator calculated using the X-ray Voxel Monte Carlo (XVMC) dose algorithm in the Monaco treatment planning system (TPS) for both low-energy (6 MV) and high-energy (15 MV) photons at cardiac implantable electronic device (CIED) depths was investigated through a comparison between MCNPX simulated out-of-field doses and measured out-of-field doses using three high spatial and sensitive active detectors. In addition, total neutron equivalent dose and fluence at CIED depths of a 15-MV dose from an Elekta Synergy accelerator were calculated, and the corresponding CIED relative neutron damage was quantified. The results showed that for 6-MV photons, the XVMC dose algorithm in Monaco underestimated out-of-field doses in all off-axis distances (average errors: -17% at distances X < 10 cm from the field edge and -31% at distances between 10 < X ≤ 16 cm from the field edge), with an increasing magnitude of underestimation for high-energy (15 MV) photons (up to 11%). According to the results, an out-of-field photon dose at a shallower CIED depth of 1 cm was associated with greater statistical uncertainty in the dose estimate compared to a CIED depth of 2 cm and clinical depth of 10 cm. Our results showed that the relative neutron damage at a CIED depth range for 15 MV photon is 36% less than that reported for 18 MV photon in the literature. | URI: | https://ahro.austin.org.au/austinjspui/handle/1/28828 | DOI: | 10.1016/j.apradiso.2021.109895 | ORCID: | 0000-0003-2945-7082 | Journal: | Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine | PubMed URL: | 34419874 | PubMed URL: | https://pubmed.ncbi.nlm.nih.gov/34419874/ | Type: | Journal Article | Subjects: | Cardiac implantable electronic devices MCNPX Monaco Monte Carlo Out-of-field dose PinPoint 3D Secondary neutrons Semiflex 3D microDiamond |
Appears in Collections: | Journal articles |
Show full item record
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.