Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/18253
Title: | Accuracy of Patient Perception of Supine Sleep. | Austin Authors: | Wallbridge, Peter D ;Churchward, Thomas J ;Worsnop, Christopher J | Affiliation: | Respiratory and Sleep Medicine Institute for Breathing and Sleep |
Issue Date: | 15-Jul-2018 | Date: | 2018-07-15 | Publication information: | Journal of Clinical Sleep Medicine : JCSM : official publication of the American Academy of Sleep Medicine 2018; 14(7): 1205-1208 | Abstract: | For clinicians involved in investigating and treating sleep disorders, understanding the accuracy of patient recall of supine sleep would allow informed comparisons between polysomnography (PSG) and patient-reported sleep in patients with supine-predominant obstructive sleep apnea. This study aims to assess the accuracy of patient perception of supine sleep. Prospective observational cohort study, assessing patient perception of total sleep and supine sleep, including duration. Data were analyzed utilizing descriptive statistics, bias-plot (Bland-Altman) analysis, and Spearman correlation (rs) to analyze relationships among continuous data. Total number of patients who underwent PSG was 518, with data from 368 of these patients analyzed. Most of these patients underwent diagnostic PSG (49.2%). Patients were excluded because of missing or incomplete data (n = 133) or immobility (n = 17). Some patients (n = 97, 26%) did not perceive supine sleep, with 34 (35% of those with unperceived supine sleep or 9% of whole group) of these having more than 60 minutes of PSG supine sleep (range 0-305.5 minutes). All "unsure" patients (n = 8, 2.2%) had significant supine sleep recorded (31.5-257.5 minutes). For the presence of any PSG supine sleep, questioning had a sensitivity of 77.9%, specificity 72.7% with positive predictive value of 96.7% and negative predictive value of 24.5%. There was a significant correlation (rs = 0.63, P < .0001) between perceived and PSG supine sleep, but wide limits of agreement (-246.9 to 194.2 minutes). In patients undergoing in-laboratory PSG, the perception of supine sleep predicts the presence of PSG supine sleep. However, questioning patients has a poor negative predictive value and patient estimates of supine sleep duration are inaccurate. | URI: | https://ahro.austin.org.au/austinjspui/handle/1/18253 | DOI: | 10.5664/jcsm.7226 | ORCID: | 0000-0003-1471-9318 |
Journal: | Journal of Clinical Sleep Medicine : JCSM | PubMed URL: | 29991424 | Type: | Journal Article | Subjects: | accuracy agreement obstructive sleep apnea patient perception sleep position sleep-disordered breathing |
Appears in Collections: | Journal articles |
Show full item record
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.