Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/12204
Title: Hybrid measurement to achieve satisfactory precision in perioperative cardiac output monitoring.
Austin Authors: Peyton, Philip J 
Affiliation: Department of Anaesthesia, Austin Health, Heidelberg, Victoria, Australia, and University Department of Surgery, University of Melbourne, Melbourne, Victoria, Australia
Issue Date: 1-May-2014
Publication information: Anaesthesia and Intensive Care; 42(3): 340-9
Abstract: Advanced haemodynamic monitoring employing minimally invasive cardiac output measurement may lead to significant improvements in patient outcomes in major surgery. However, the precision (scatter) of measurement of available generic technologies has been shown to be unsatisfactory with percentage error of agreement with bolus thermodilution (% error) of 40% to 50%. Simultaneous measurement and averaging by two or more technologies may reduce random measurement scatter and improve precision. This concept, called the hybrid method, was tested by comparing accuracy and precision of measurement relative to bolus thermodilution using combinations of three component methods. Thirty patients scheduled for either elective cardiac surgery or liver transplantation were studied. Agreement with simultaneous bolus thermodilution of hybrid combinations of continuous thermodilution (QtCCO) or Vigeleo™/FloTrac™ pulse contour measurement (QtFT) with pulmonary Capnotracking (QtCO2) was assessed pre- and post-cardiopulmonary bypass or pre- and post-reperfusion of the donor liver and compared with that of the component methods alone. Hybridisation of QtCO2 (% error 42.2) and QtCCO (% error 51.3) achieved significantly better precision (% error 31.3) than the component methods (P=0.0004) and (P=0.0195). Due to poor inherent precision of QtFT (% error 82.8), hybrid combination of QtFT with QtCO2 did not result in better precision than QtCO2 alone. Hybrid measurement can approach a 30% error, which is recommended as the upper limit for acceptability. This is a practical option where at least one component method, such as Capnotracking, is automated and does not increase the cost or complexity of the measurement process.
Gov't Doc #: 24794474
URI: https://ahro.austin.org.au/austinjspui/handle/1/12204
Journal: Anaesthesia and Intensive Care
URL: https://pubmed.ncbi.nlm.nih.gov/24794474
Type: Journal Article
Subjects: Capnotrack
cardiac output measurement
hybrid
thermodilution
Adult
Aged
Aged, 80 and over
Cardiac Output
Female
Humans
Male
Middle Aged
Monitoring, Physiologic.methods
Perioperative Period
Thermodilution.methods
Appears in Collections:Journal articles

Show full item record

Page view(s)

34
checked on Aug 23, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.