Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/10844
Title: Reproducibility of cardiac output measurement by the nitrous oxide rebreathing technique.
Austin Authors: Peyton, Philip J ;Bailey, Michael J;Thompson, Bruce R
Affiliation: Department of Anaesthesia, Austin Hospital, University of Melbourne, Melbourne, Australia
Issue Date: 19-Jun-2009
Publication information: Journal of Clinical Monitoring and Computing 2009; 23(4): 233-6
Abstract: Techniques for the measurement of cardiac output from soluble gas uptake by the lungs include the rebreathing method using nitrous oxide. The accuracy of this technique is well accepted, but its repeatability of measurement (precision) has not been well documented. We assessed the repeatability of measurements of pulmonary blood flow by the Innocor, a device employing the nitrous oxide rebreathing method. Successive paired measurements of pulmonary blood flow were made separated by a 5 min interval by the nitrous oxide rebreathing method, in 8 patients pre- or post cardiac surgery, and in 8 healthy volunteers. The standard deviation of the difference between first and second measurements was 0.84 l/min in the cardiac surgery group, and 1.25 l/min in the healthy volunteers. There was no significant bias in successive paired measurements of pulmonary blood flow in either the cardiac surgery patients (mean [95%CI] = -0.02 l/min [-0.62 to 0.57] or the healthy volunteers (0.00 l/min [-0.88 to 0.88]). Intra-class correlation coefficients for the healthy and cardiac patients were 0.77 and 0.64 respectively. Multiple measurements should be made and averaged when using the inert gas rebreathing technique for pulmonary blood flow determination. When comparing agreement with other methods for cardiac output measurement, the internal consistency of both methods should be considered.
Gov't Doc #: 19543798
URI: https://ahro.austin.org.au/austinjspui/handle/1/10844
DOI: 10.1007/s10877-009-9187-7
Journal: Journal of clinical monitoring and computing
URL: https://pubmed.ncbi.nlm.nih.gov/19543798
Type: Journal Article
Subjects: Administration, Inhalation
Adult
Aged
Anesthesia, Closed-Circuit.methods
Carbon Dioxide.chemistry
Cardiac Output.physiology
Hemodynamics
Humans
Middle Aged
Nitrous Oxide.metabolism
Pressure
Pulmonary Circulation.physiology
Reproducibility of Results
Respiratory Mechanics
Thoracic Surgery
Appears in Collections:Journal articles

Files in This Item:
File SizeFormat 
19543798.pdf47.49 kBAdobe PDFView/Open
Show full item record

Page view(s)

44
checked on Nov 27, 2024

Download(s)

86
checked on Nov 27, 2024

Google ScholarTM

Check