Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/9908
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPhal, Pramit Men
dc.contributor.authorBrooks, Duncan Marken
dc.contributor.authorWolfe, Roryen
dc.date.accessioned2015-05-15T23:11:24Z
dc.date.available2015-05-15T23:11:24Z
dc.date.issued2005-05-01en
dc.identifier.citationAjr. American Journal of Roentgenology; 184(5): 1652-6en
dc.identifier.govdoc15855133en
dc.identifier.otherPUBMEDen
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/9908en
dc.description.abstractA phantom model of lesions in the human liver with simulated ribs was used to test an ultrasound probe-guided sonographic biopsy technique. The aim of the experiment was to compare biopsy time and sample quality between freehand and probe-guided methods of sonographic biopsy.Ten operators with a range of clinical biopsy experience were tested. Each operator was given two phantoms containing four targets. Each target was biopsied with both biopsy methods. Data collected included procedure time and sample quality in the biopsy specimen. Analyses were stratified by level of operator experience.Median biopsy time was 23 sec with the ultrasound probe guide and 32 sec freehand. Differences between probe-guided and freehand pairs of measurements approximately followed a normal distribution. The mean time difference between probe-guided and freehand times to complete biopsy was -20 sec (95% confidence interval, -35 to -5 sec; p = 0.01). Analysis of sample quality across all operators showed no difference.The ultrasound probe-guided technique of sonographic biopsy could be used in a complex phantom model, and there was a statistically significant time benefit with the use of probe guides compared with the freehand biopsy technique. This benefit was greatest for inexperienced operators. There was no difference in sample quality between the probe-guided and freehand techniques.en
dc.language.isoenen
dc.subject.otherAnalysis of Varianceen
dc.subject.otherBiopsy.methodsen
dc.subject.otherHumansen
dc.subject.otherLiver Diseases.pathology.ultrasonographyen
dc.subject.otherObserver Variationen
dc.subject.otherPhantoms, Imagingen
dc.subject.otherTime Factorsen
dc.subject.otherUltrasonography, Interventionalen
dc.titleSonographically guided biopsy of focal lesions: a comparison of freehand and probe-guided techniques using a phantom.en
dc.typeJournal Articleen
dc.identifier.journaltitleAJR. American journal of roentgenologyen
dc.identifier.affiliationDepartment of Radiology, Austin Health, The University of Melbourne, Studley Rd., Heidelberg, Melbourne, Victoria 3084, Australiaen
dc.identifier.doi10.2214/ajr.184.5.01841652en
dc.description.pages1652-6en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/15855133en
dc.type.austinJournal Articleen
local.name.researcherBrooks, Duncan Mark
item.fulltextNo Fulltext-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextnone-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.author.deptRadiology-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

24
checked on Dec 17, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.