Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/35405
Title: An automated denoising pipeline for multi-band multi-echo fMRI data
Austin Authors: Tahayori, Bahman;Smith, Robert;Vaughan, David;Pierre, Eric;Jackson, Graeme;Abbott, David F 
Affiliation: The Florey Institute of Neuroscience and Mental Health
Medicine (University of Melbourne)
Austin Health
Issue Date: Jul-2024
Abstract: Aim Multi-Band Multi-Echo (MBME) imaging in functional MRI (fMRI) provides fast data acquisition and improves the signal-to-noise ratio by leveraging the echo-time (TE) dependency of the signal to distinguish between Blood Oxygenation-Level Dependent (BOLD) and non-BOLD signals. TE Dependent ANAlysis (TEDANA) is an open-source tool that processes MBME fMRI data to produce a denoised dataset. However, previous studies indicated that TEDANA might inadvertently remove BOLD signal along with noise. This study aimed to improve the TEDANA framework by introducing a Modified Independent Component Analysis Denoising (MICAD) framework. The enhancements included 1) applying thermal denoising to raw data, 2) using a robust method for component analysis, and 3) refining the classification algorithm. Methods We used the Australian Epilepsy Project (AEP) language task fMRI data of 240 participants to compare the denoising frameworks. We employed fMRIPrep for typical processing of fMRI data and used the iBrain Analysis Toolbox for SPM (iBT) to estimate the activation map for each subject. We calculated mean t-score and Activation Volume (AV) within a language region of interest for comparing pipelines. Furthermore, two clinicians with expertise in language network identification from our centre evaluated the performance of the pipelines for a subset of the subjects. Results A significant proportion of subjects, over 80%, showed a higher AV/t-score within the language region when processed with MICAD. More importantly, in contrast to TEDANA, the proposed method did not result in any significant removal of AV reduction and achieved reasonable results at an individual subject level. Furthermore, clinicians’ evaluations were well aligned with the AV measure. Conclusion The MICAD pipeline is sufficiently robust to reliably yield acceptable results for individual subjects, a pre-requisite for clinical research in AEP. The MICAD pipeline can be extended to resting-state fMRI data in an automated pipeline. Impact The proposed automated pipeline will be applied to the AEP resting-state fMRI data to achieve more consistent, reliable results. Furthermore, the framework can be applied to any large fMRI dataset as it does not require manual inspection of the denoising result.
Description: ResearchFest 2024
Conference Name: ResearchFest 2024
Conference Location: Austin Health
URI: https://ahro.austin.org.au/austinjspui/handle/1/35405
ORCID: 0000-0002-4927-0023
0000-0002-7259-8238
Type: Conference Presentation
Appears in Collections:ResearchFest abstracts

Files in This Item:
File Description SizeFormat 
ResearchFest_2024_tedana.pptxPoster by B. Tahayori et al.4.41 MBMicrosoft Powerpoint XMLView/Open
Show full item record

Page view(s)

210
checked on Dec 26, 2024

Download(s)

36
checked on Dec 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.