Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/35405
Title: | An automated denoising pipeline for multi-band multi-echo fMRI data | Austin Authors: | Tahayori, Bahman;Smith, Robert;Vaughan, David;Pierre, Eric;Jackson, Graeme;Abbott, David F | Affiliation: | The Florey Institute of Neuroscience and Mental Health Medicine (University of Melbourne) Austin Health |
Issue Date: | Jul-2024 | Abstract: | Aim Multi-Band Multi-Echo (MBME) imaging in functional MRI (fMRI) provides fast data acquisition and improves the signal-to-noise ratio by leveraging the echo-time (TE) dependency of the signal to distinguish between Blood Oxygenation-Level Dependent (BOLD) and non-BOLD signals. TE Dependent ANAlysis (TEDANA) is an open-source tool that processes MBME fMRI data to produce a denoised dataset. However, previous studies indicated that TEDANA might inadvertently remove BOLD signal along with noise. This study aimed to improve the TEDANA framework by introducing a Modified Independent Component Analysis Denoising (MICAD) framework. The enhancements included 1) applying thermal denoising to raw data, 2) using a robust method for component analysis, and 3) refining the classification algorithm. Methods We used the Australian Epilepsy Project (AEP) language task fMRI data of 240 participants to compare the denoising frameworks. We employed fMRIPrep for typical processing of fMRI data and used the iBrain Analysis Toolbox for SPM (iBT) to estimate the activation map for each subject. We calculated mean t-score and Activation Volume (AV) within a language region of interest for comparing pipelines. Furthermore, two clinicians with expertise in language network identification from our centre evaluated the performance of the pipelines for a subset of the subjects. Results A significant proportion of subjects, over 80%, showed a higher AV/t-score within the language region when processed with MICAD. More importantly, in contrast to TEDANA, the proposed method did not result in any significant removal of AV reduction and achieved reasonable results at an individual subject level. Furthermore, clinicians’ evaluations were well aligned with the AV measure. Conclusion The MICAD pipeline is sufficiently robust to reliably yield acceptable results for individual subjects, a pre-requisite for clinical research in AEP. The MICAD pipeline can be extended to resting-state fMRI data in an automated pipeline. Impact The proposed automated pipeline will be applied to the AEP resting-state fMRI data to achieve more consistent, reliable results. Furthermore, the framework can be applied to any large fMRI dataset as it does not require manual inspection of the denoising result. | Description: | ResearchFest 2024 | Conference Name: | ResearchFest 2024 | Conference Location: | Austin Health | URI: | https://ahro.austin.org.au/austinjspui/handle/1/35405 | ORCID: | 0000-0002-4927-0023 0000-0002-7259-8238 |
Type: | Conference Presentation |
Appears in Collections: | ResearchFest abstracts |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ResearchFest_2024_tedana.pptx | Poster by B. Tahayori et al. | 4.41 MB | Microsoft Powerpoint XML | View/Open |
Page view(s)
210
checked on Dec 26, 2024
Download(s)
36
checked on Dec 26, 2024
Google ScholarTM
Check
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.