Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/33395
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVillalobos, Joel-
dc.contributor.authorPayne, Sophie C-
dc.contributor.authorWard, Glenn M-
dc.contributor.authorAndrikopoulos, Sofianos-
dc.contributor.authorHyakumura, Tomoko-
dc.contributor.authorMacIsaac, Richard J-
dc.contributor.authorFallon, James B-
dc.date2023-
dc.date.accessioned2023-07-26T06:37:03Z-
dc.date.available2023-07-26T06:37:03Z-
dc.date.issued2023-07-18-
dc.identifier.citationBioelectronic Medicine 2023-07-18; 9(1)en_US
dc.identifier.issn2332-8886-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/33395-
dc.description.abstractAutonomic nerve stimulation is used as a treatment for a growing number of diseases. We have previously demonstrated that application of efferent vagus nerve stimulation (eVNS) has promising glucose lowering effects in a rat model of type 2 diabetes. This paradigm combines high frequency pulsatile stimulation to block nerve activation in the afferent direction with low frequency stimulation to activate the efferent nerve section. In this study we explored the effects of the parameters for nerve blocking on the ability to inhibit nerve activation in the afferent direction. The overarching aim is to establish a blocking stimulation strategy that could be applied using commercially available implantable pulse generators used in the clinic. Male rats (n = 20) had the anterior abdominal vagus nerve implanted with a multi-electrode cuff. Evoked compound action potentials (ECAP) were recorded at the proximal end of the electrode cuff. The efficacy of high frequency stimulation to block the afferent ECAP was assessed by changes in the threshold and saturation level of the response. Blocking frequency and duty cycle of the blocking pulses were varied while maintaining a constant 4 mA current amplitude. During application of blocking at lower frequencies (≤ 4 kHz), the ECAP threshold increased (ANOVA, p < 0.001) and saturation level decreased (p < 0.001). Application of higher duty cycles (> 70%) led to an increase in evoked neural response threshold (p < 0.001) and a decrease in saturation level (p < 0.001). During the application of a constant pulse width and frequency (1 or 1.6 kHz, > 70% duty cycle), the charge delivered per pulse had a significant influence on the magnitude of the block (ANOVA, p = 0.003), and was focal (< 2 mm range). This study has determined the range of frequencies, duty cycles and currents of high frequency stimulation that generate an efficacious, focal axonal block of a predominantly C-fiber tract. These findings could have potential application for the treatment of type 2 diabetes.en_US
dc.language.isoeng-
dc.subjectBioelectric medicineen_US
dc.subjectMedical devicesen_US
dc.subjectMetabolic diseaseen_US
dc.subjectNerve blockingen_US
dc.subjectPeripheral nerve stimulationen_US
dc.titleStimulation parameters for directional vagus nerve stimulation.en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleBioelectronic Medicineen_US
dc.identifier.affiliationBionics Institute, East Melbourne, Vic, Australia.en_US
dc.identifier.affiliationDepartment of Medical Bionics, University of Melbourne, Parkville, Vic, Australia.en_US
dc.identifier.affiliationDepartment of Endocrinology and Diabetes, St Vincent's Hospital Melbourne, Fitzroy, Vic, Australia.;Department of Medicine, St Vincent's Hospital Melbourne, University of Melbourne, Fitzroy, Vic, Australia.en_US
dc.identifier.affiliationAustralian Centre for Accelerating Diabetes Innovations, University of Melbourne, Parkville, Australia.;Department of Medicine (Austin Health), University of Melbourne, Heidelberg, Vic, Australia.en_US
dc.identifier.affiliationMedicine (University of Melbourne)en_US
dc.identifier.affiliationAustralian Diabetes Society, Sydney, NSW, Australia.en_US
dc.identifier.doi10.1186/s42234-023-00117-2en_US
dc.type.contentTexten_US
dc.identifier.pubmedid37464423-
dc.description.volume9-
dc.description.issue1-
dc.description.startpage16-
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

36
checked on Nov 28, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.