Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/32769
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSansom, Benjamin-
dc.contributor.authorRiley, Brooke-
dc.contributor.authorUdy, Andrew-
dc.contributor.authorSriram, Shyamala-
dc.contributor.authorPresneill, Jeffrey-
dc.contributor.authorBellomo, Rinaldo-
dc.date2023-
dc.date.accessioned2023-04-26T05:24:28Z-
dc.date.available2023-04-26T05:24:28Z-
dc.date.issued2023-04-19-
dc.identifier.citationBlood Purification 2023; 52(6)en_US
dc.identifier.issn1421-9735-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/32769-
dc.description.abstractTreatment with continuous renal replacement therapy (CRRT) is common during extracorporeal membrane oxygenation (ECMO). Such ECMO-CRRT has specific technical characteristics, which may affect circuit life. Accordingly, we studied CRRT haemodynamics and circuit life during ECMO. ECMO and non-ECMO-CRRT treatments in two adult intensive care units were compared using data collected over a 3-year period. A potential predictor of circuit survival identified in a 60% training data subset as a time-varying covariate within a Cox proportional hazard model was subsequently assessed in the complementary remaining data (40%). Median [interquartile range] CRRT circuit life was greater when associated with ECMO (28.8 [14.0-65.2] vs. 20.2 [9.8-40.2] h, p < 0.0001). Access, return, prefilter, and effluent pressures were also greater during ECMO. Higher ECMO flows were associated with higher access and return pressures. Classification and regression tree analysis identified an association between high access pressures and accelerated circuit failure, while both first access pressures ≥190 mm Hg (HR 1.58 [1.09-2.30]) and patient weight (HR 1.85 [1.15-2.97] third tertile vs. first tertile) were independently associated with circuit failure in a multivariable Cox model. Access dysfunction was associated with a stepwise increase in transfilter pressure, suggesting a potential mechanism of membrane injury. CRRT circuits used in conjunction with ECMO have a longer circuit life than usual CRRT despite exposure to higher circuit pressures. Markedly elevated access pressures, however, may predict early CRRT circuit failure during ECMO, possibly via progressive membrane thrombosis as evidenced by increased transfilter pressure gradients.en_US
dc.language.isoeng-
dc.subjectAcute kidney injuryen_US
dc.subjectContinuous renal replacement therapyen_US
dc.subjectCritical illnessen_US
dc.subjectExtracorporeal therapyen_US
dc.subjectHaemodiafiltrationen_US
dc.titleContinuous Renal Replacement Therapy during Extracorporeal Membrane Oxygenation: Circuit Haemodynamics and Circuit Failure.en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleBlood Purificationen_US
dc.identifier.affiliationDepartment of Intensive Care, The Royal Melbourne Hospital, Melbourne, Victoria, Australia.;Department of Critical Care, The University of Melbourne, Melbourne, Victoria, Australia.en_US
dc.identifier.affiliationDepartment of Intensive Care and Hyperbaric Medicine, The Alfred, Melbourne, Victoria, Australia.en_US
dc.identifier.affiliationAustralian and New Zealand Intensive Care Research Centre, School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia.en_US
dc.identifier.affiliationIntensive Careen_US
dc.identifier.doi10.1159/000529928en_US
dc.type.contentTexten_US
dc.identifier.pubmedid37075718-
dc.description.startpage1-
dc.description.endpage10-
local.name.researcherBellomo, Rinaldo
item.languageiso639-1en-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.deptIntensive Care-
crisitem.author.deptData Analytics Research and Evaluation (DARE) Centre-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

24
checked on Nov 5, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.