Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/32559
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChen, Janet X C-
dc.contributor.authorFong, Jenny-
dc.contributor.authorLim, Han S-
dc.contributor.authorTeh, Andrew W-
dc.contributor.authorHan, Hui-Chen-
dc.date2023-03-
dc.date.accessioned2023-04-14T02:46:40Z-
dc.date.available2023-04-14T02:46:40Z-
dc.date.issued2023-06-13-
dc.identifier.citationJournal of Electrocardiology 2023; 79en_US
dc.identifier.issn1532-8430-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/32559-
dc.description.abstractWe report a case of an implant cardiac defibrillator (ICD) patient who an ICD implanted for ventricular fibrillation (VF) related to mitral valve prolapse. He has 2 episodes of VF in his device lives. First episode of VF in year 2016 was initiated after a pause related to the MVP™ algorithm with a critically timed PVC. MVP™ was turned off which prevented further VF episodes. However, MVP™ was turned back on at the device replacement in 2018. A second VF episode developed with similar mechanism in 2021 and MVP™ was subsequently turned off with no further VF recorded. This case highlights the importance of recognizing the mechanism of initiation of tachy-arrhythmia episodes and serves as an important reminder regarding optimization of device settings at the time of replacement.en_US
dc.language.isoeng-
dc.subjectDevice settingsen_US
dc.subjectICDen_US
dc.subjectManaged ventricular pacingen_US
dc.subjectMitral valve prolapseen_US
dc.subjectVentricular fibrillationen_US
dc.titleVentricular fibrillation episodes related to managed ventricular pacing algorithm in a patient with mitral valve prolapse - "Arrhythmic MVP due to MVP".en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleJournal of Electrocardiologyen_US
dc.identifier.affiliationAustin Health, Victoria, Australia.en_US
dc.identifier.affiliationEastern Health Clinical School, Monash University, Victoria, Australiaen_US
dc.identifier.affiliationUniversity of Melbourne Clinical Schoolen_US
dc.identifier.affiliationMonash Medical Center, Victoria, Australiaen_US
dc.identifier.doi10.1016/j.jelectrocard.2023.03.008en_US
dc.type.contentTexten_US
dc.identifier.pubmedid36948089-
dc.description.volume79-
dc.description.startpage58-
dc.description.endpage60-
local.name.researcherHan, Hui-Chen
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeJournal Article-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.languageiso639-1en-
crisitem.author.deptCardiology-
crisitem.author.deptCardiology-
crisitem.author.deptCardiology-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

44
checked on Oct 3, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.