Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/26723
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKnock, Stuart A-
dc.contributor.authorMagee, Michelle-
dc.contributor.authorStone, Julia E-
dc.contributor.authorGanesan, Saranea-
dc.contributor.authorMulhall, Megan D-
dc.contributor.authorLockley, Steven W-
dc.contributor.authorHoward, Mark E-
dc.contributor.authorRajaratnam, Shantha M W-
dc.contributor.authorSletten, Tracey L-
dc.contributor.authorPostnova, Svetlana-
dc.date2021-06-10-
dc.date.accessioned2021-06-14T23:57:08Z-
dc.date.available2021-06-14T23:57:08Z-
dc.date.issued2021-
dc.identifier.citationSleep 2021; 44(11)en
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/26723-
dc.description.abstractThe study aimed to, for the first time, (i) compare sleep, circadian phase, and alertness of Intensive Care Unit (ICU) nurses working rotating shifts with those predicted by a model of arousal dynamics; and (ii) investigate how different environmental constraints affect predictions and agreement with data. The model was used to simulate individual sleep-wake cycles, urinary 6-sulphatoxymelatonin (aMT6s) profiles, subjective sleepiness on the Karolinska Sleepiness Scale (KSS), and performance on a Psychomotor Vigilance Task (PVT) of 21 ICU nurses working day, evening, and night shifts. Combinations of individual shift schedules, forced wake time before/after work and lighting, were used as inputs to the model. Predictions were compared to empirical data. Simulations with self-reported sleep as an input were performed for comparison. All input constraints produced similar prediction for KSS, with 56-60% of KSS scores predicted within ±1 on a day and 48-52% on a night shift. Accurate prediction of an individual's circadian phase required individualised light input. Combinations including light information predicted aMT6s acrophase within ±1 h of the study data for 65% and 35-47% of nurses on diurnal and nocturnal schedules. Minute-by-minute sleep-wake state overlap between the model and the data was between 81±6% and 87±5% depending on choice of input constraint. The use of individualised environmental constraints in the model of arousal dynamics allowed for accurate prediction of alertness, circadian phase and sleep for more than half of the nurses. Individual differences in physiological parameters will need to be accounted for in the future to further improve predictions.en
dc.language.isoeng-
dc.subjectalertnessen
dc.subjectcircadian rhythmsen
dc.subjecthealthcareen
dc.subjectnursesen
dc.subjectquantitative modellingen
dc.subjectrotating shiftworken
dc.subjectsleepen
dc.subjectsleepinessen
dc.titlePrediction Of Shiftworker Alertness, Sleep, And Circadian Phase Using A Model Of Arousal Dynamics Constrained By Shift Schedules And Light Exposure.en
dc.typeJournal Articleen
dc.identifier.journaltitleSleepen
dc.identifier.affiliationDivision of Sleep Medicine, Harvard Medical School, Boston, MA, USAen
dc.identifier.affiliationInstitute for Breathing and Sleepen
dc.identifier.affiliationSydney Nano, the University of Sydney, Camperdown, Australiaen
dc.identifier.affiliationWoolcock Institute of Medical Research, Glebe, Australiaen
dc.identifier.affiliationCooperative Research Centre for Alertness, Safety and Productivity, Melbourne, Australiaen
dc.identifier.affiliationTurner Institute for Brain and Mental Health, School of Psychological Sciences, Monash University, Clayton, Australiaen
dc.identifier.affiliationDivision of Sleep and Circadian Disorders, Departments of Medicine and Neurology, Brigham and Women's Hospital, Boston, MA, USAen
dc.identifier.affiliationThe University of Sydney, School of Physics, Camperdown, Australiaen
dc.identifier.doi10.1093/sleep/zsab146en
dc.type.contentTexten
dc.identifier.orcid0000-0001-6642-0882en
dc.identifier.pubmedid34111278-
local.name.researcherHoward, Mark E
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeJournal Article-
crisitem.author.deptInstitute for Breathing and Sleep-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

14
checked on Aug 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.