Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/26425
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJuncos, Luis A-
dc.contributor.authorChandrashekar, Kiran-
dc.contributor.authorKarakala, Nithin-
dc.contributor.authorBaldwin, Ian C-
dc.date2021-05-03-
dc.date.accessioned2021-05-10T07:13:22Z-
dc.date.available2021-05-10T07:13:22Z-
dc.date.issued2021-
dc.identifier.citationSeminars in dialysis 2021; 34(6): 406-415en
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/26425-
dc.description.abstractThe advances in the technology for providing continuous renal replacement therapy (CRRT) have led to an increase in its utilization throughout the world. However, circuit life continues to be a major problem. It leads not only to decreased delivery of dialysis but also causes blood loss, waste of disposables, alters dose delivery of medications and nutrition, and increases nurse workload, all of which increases healthcare cost. Premature circuit failure can be caused by numerous factors that can be difficult to dissect out. The first component is the vascular access; without a well-placed, functioning access, delivery of CRRT becomes very difficult. This is usually accomplished by placing a short-term dialysis catheter into either the right internal jugular or femoral vein. The tips should be located at the caval atrial junction or inferior vena cava. In addition to establishing suitable vascular access, a comprehensive understanding of the circuit facilitates the development of a methodical approach in providing efficient CRRT characterized by optimal circuit life. Moreover, it aids in determining the cause of circuit failure in patients experiencing recurrent episodes. This review therefore summarizes the essential points that guide providers in establishing optimal vascular access. We then provide an overview of the main components of the CRRT circuit including the blood and fluid pumps, the hemofilter, and pressure sensors, which will assist in identifying the key mechanisms contributing to premature failure of the CRRT circuit.en
dc.language.isoeng-
dc.titleVascular access, membranes and circuit for CRRT.en
dc.typeJournal Articleen
dc.identifier.journaltitleSeminars in Dialysisen
dc.identifier.affiliationIntensive Careen
dc.identifier.affiliationDepartment of Internal Medicine, Central Arkansas Veterans Healthcare System and University of Arkansas for Medical Sciences, Little Rock, AR, USAen
dc.identifier.doi10.1111/sdi.12977en
dc.type.contentTexten
dc.identifier.orcid0000-0002-4630-2747en
dc.identifier.orcid0000-0001-9173-4429en
dc.identifier.pubmedid33939859-
local.name.researcherBaldwin, Ian C
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
crisitem.author.deptIntensive Care-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

54
checked on Nov 22, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.