Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/25383
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nambiar, Mithun | - |
dc.contributor.author | Maingard, Julian | - |
dc.contributor.author | Li, Kenny | - |
dc.contributor.author | Slater, Lee-Anne | - |
dc.contributor.author | Chandra, Ronil V | - |
dc.contributor.author | Chong, Winston | - |
dc.contributor.author | Brooks, Duncan Mark | - |
dc.contributor.author | McGaw, David | - |
dc.contributor.author | Asadi, Hamed | - |
dc.date | 2020-11-19 | - |
dc.date.accessioned | 2020-11-25T04:54:38Z | - |
dc.date.available | 2020-11-25T04:54:38Z | - |
dc.date.issued | 2020-11-19 | - |
dc.identifier.citation | CVIR Endovascular 2020; 3(1): 83 | en |
dc.identifier.uri | https://ahro.austin.org.au/austinjspui/handle/1/25383 | - |
dc.description.abstract | Management of coronary artery fistula (CAF) is based on obliterating the fistula communication between the cardiac arteries and other thoracic vessels. We describe the presentation of an 85-year-old female with progressive exertional dyspnea on a background of a long standing left anterior descending diagonal to pulmonary artery fistula. We utilized neuro-interventional techniques to perform coil embolization via use of a Scepter XC dual lumen micro catheter. Dual lumen balloon catheters allow for super-selective artery interrogation, stability of balloon positioning, with less trauma to vessel architecture and accurate embolization. There were no complications and the patient reported improvement of symptoms on review. | en |
dc.language.iso | eng | - |
dc.subject | Coronary vessel anomaly | en |
dc.subject | Embolization | en |
dc.subject | Endovascular | en |
dc.subject | Fistula | en |
dc.subject | Microcatheter | en |
dc.subject | Percutaneous cardiac intervention | en |
dc.subject | Radiology | en |
dc.title | COILUMICA: coil embolization of a coronary artery to pulmonary artery fistula via novel dual lumen micro catheter technique. | en |
dc.type | Journal Article | en |
dc.identifier.journaltitle | CVIR Endovascular | en |
dc.identifier.affiliation | Radiology | en |
dc.identifier.affiliation | Interventional Service, Monash Heart, Monash Medical Centre, 246 Clayton Road, VIC, 3168, Clayton, Australia | en |
dc.identifier.affiliation | Faculty of Medicine, Nursing and Health Sciences, Monash University, Wellington Road, Clayton, VIC, 3800, Australia | en |
dc.identifier.affiliation | Interventional Neuroradiology Unit, Monash Imaging, Monash Medical Centre, 246 Clayton Road, Clayton, VIC, 3168, Australia | en |
dc.identifier.affiliation | School of Medicine, Faculty of Health, Deakin University, 75 Pigdons Road, Geelong, VIC, 3216, Australia | en |
dc.identifier.doi | 10.1186/s42155-020-00177-4 | en |
dc.type.content | Text | en |
dc.identifier.orcid | 0000-0002-7332-6744 | en |
dc.identifier.pubmedid | 33210181 | - |
local.name.researcher | Asadi, Hamed | |
item.grantfulltext | none | - |
item.openairetype | Journal Article | - |
item.languageiso639-1 | en | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Radiology | - |
crisitem.author.dept | Radiology | - |
Appears in Collections: | Journal articles |
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.