Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/25149
Title: The Functional Tactile Object Recognition Test: A Unidimensional Measure With Excellent Internal Consistency for Haptic Sensing of Real Objects After Stroke.
Austin Authors: Carey, Leeanne M ;Mak-Yuen, Yvonne Y K;Matyas, Thomas A
Affiliation: Department of Occupational Therapy, Social Work and Social Policy, School of Allied Health, Human Services and Sport, College of Science, Health and Engineering, La Trobe University, Melbourne, VIC, Australia
The Florey Institute of Neuroscience and Mental Health
Issue Date: 23-Sep-2020
Date: 2020-09-23
Publication information: Frontiers in Neuroscience 2020; 14: 542590
Abstract: Our hands, with their exquisite sensors, work in concert with our sensing brain to extract sensory attributes of objects as we engage in daily activities. One in two people with stroke experience impaired body sensation, with negative impact on hand use and return to previous valued activities. Valid, quantitative tools are critical to measure somatosensory impairment after stroke. The functional Tactile Object Recognition Test (fTORT) is a quantitative measure of tactile (haptic) object recognition designed to test one's ability to recognize everyday objects across seven sensory attributes using 14 object sets. However, to date, knowledge of the nature of object recognition errors is limited, and the internal consistency of performance across item scores and dimensionality of the measure have not been established. To describe the original development and construction of the test, characterize the distribution and nature of performance errors after stroke, and to evaluate the internal consistency of item scores and dimensionality of the fTORT. Data from existing cohorts of stroke survivors (n = 115) who were assessed on the fTORT quantitative measure of sensory performance were extracted and pooled. Item and scale analyses were conducted on the raw item data. The distribution and type of errors were characterized. The 14 item sets of the fTORT form a well-behaved unidimensional scale and demonstrate excellent internal consistency (Cronbach alpha of 0.93). Deletion of any item failed to improve the Cronbach score. Most items displayed a bimodal score distribution, with function and attribute errors (score 0) or correct response (score 3) being most common. A smaller proportion of one- or two-attribute errors occurred. The total score range differentiated performance over a wide range of object recognition impairment. Unidimensional scale and similar factor loadings across all items support simple addition of the 14 item scores on the fTORT. Therapists can use the fTORT to quantify impaired tactile object recognition in people with stroke based on the current set of items. New insights on the nature of haptic object recognition impairment after stroke are revealed.
URI: https://ahro.austin.org.au/austinjspui/handle/1/25149
DOI: 10.3389/fnins.2020.542590
Journal: Frontiers in Neuroscience
PubMed URL: 33071730
ISSN: 1662-4548
Type: Journal Article
Subjects: assess
haptic
object recognition
perception
sensation
somatosensation
Stroke
touch
Appears in Collections:Journal articles

Show full item record

Page view(s)

58
checked on Dec 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.