Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/20976
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPeyton, Philip J-
dc.contributor.authorMarsh, Harry-
dc.contributor.authorThompson, Bruce R-
dc.date2019-06-06-
dc.date.accessioned2019-06-19T06:29:49Z-
dc.date.available2019-06-19T06:29:49Z-
dc.date.issued2019-05-
dc.identifier.citationAnaesthesia and Intensive Care 2019; 47(3):267-273-
dc.identifier.issn0310-057X-
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/20976-
dc.description.abstractLung gas exchange efficiency deteriorates during general anaesthesia due to ventilation-perfusion ( V/Q) scatter. Propofol total intravenous anaesthesia (TIVA) may preserve V/Q matching better than inhalational agents. We compared V/Q matching in patients randomized to either TIVA or sevoflurane anaesthesia, using deadspace and shunt measurements and the MIGET (Multiple Inert Gas Elimination Technique). Baseline arterial blood and mixed expired gas sampling was done before induction and repeated after one to two hours of relaxant general anaesthesia in 20 patients, supine with controlled ventilation at an FiO2 of 0.3 and a target end-tidal PCO2 of 30-35 mmHg. Blood samples for MIGET were processed after headspace equilibration by gas chromatography. The primary endpoint was a comparison of the two groups in the change from baseline of absolute difference between log standard deviation of ventilation and blood flow distributions (∂(σV-σQ)). Deadspace fraction increased and PaO2/FiO2 ratio decreased across both groups overall with anaesthesia, but change in deadspace was not different between groups (mean (standard deviation, SD) sevoflurane 21.8% (11.7%) versus TIVA 20.5% (10.6%), P = 0.601). Change in PaO2/FiO2 ratio was also similar between groups (mean (SD) sevoflurane -51.9 (69.1) mmHg versus TIVA -78.3 (76.9) mmHg, P = 0.43), as was change in shunt fraction (δQs/Qt mean (SD) sevoflurane -5.1% (12.6%) versus TIVA 0.4% (7.7%), P = 0.174). The primary endpoint ∂(σV-σQ) was not different between sevoflurane and propofol TIVA groups (mean (SD) 0.17 (0.81) versus 0.17 (0.29), P = 0.94). TIVA did not better preserve V/Q matching in patients undergoing anaesthesia with controlled ventilation compared with sevoflurane.-
dc.language.isoeng-
dc.subjectVentilation–perfusion ratio-
dc.subjectanaesthesiology-
dc.subjectinhalational anaesthesia-
dc.subjectintravenous anaesthesia-
dc.subjectpulmonary gas exchange-
dc.titleIntravenous versus inhalational anaesthesia and lung ventilation-perfusion matching.-
dc.typeJournal Article-
dc.identifier.journaltitleAnaesthesia and Intensive Care-
dc.identifier.affiliationDepartment of Respiratory Medicine, Alfred Health, Central Clinical School, Monash University, Melbourne, Australiaen
dc.identifier.affiliationAnaesthesia, Perioperative and Pain Medicine Unit, Melbourne Medical School, University of Melbourne, Melbourne, Australiaen
dc.identifier.affiliationDepartment of Anaesthesia, Austin Health, Heidelberg, Victoria, Australiaen
dc.identifier.affiliationInstitute for Breathing and Sleep, Austin Health, Heidelberg, Victoria, Australiaen
dc.identifier.doi10.1177/0310057X19845378-
dc.identifier.orcid0000-0003-1185-2869-
dc.identifier.pubmedid31169407-
dc.type.austinJournal Article-
local.name.researcherMarsh, Harry
item.languageiso639-1en-
item.openairetypeJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.cerifentitytypePublications-
crisitem.author.deptAnaesthesia-
crisitem.author.deptInstitute for Breathing and Sleep-
crisitem.author.deptAnaesthesia-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

34
checked on Nov 6, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.