Please use this identifier to cite or link to this item:
https://ahro.austin.org.au/austinjspui/handle/1/18462
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Manning, Todd G | - |
dc.contributor.author | Papa, Nathan | - |
dc.contributor.author | Perera, Marlon | - |
dc.contributor.author | McGrath, Shannon | - |
dc.contributor.author | Christidis, Daniel | - |
dc.contributor.author | Khan, Munad | - |
dc.contributor.author | O'Beirne, Richard | - |
dc.contributor.author | Campbell, Nicholas | - |
dc.contributor.author | Bolton, Damien M | - |
dc.contributor.author | Lawrentschuk, Nathan | - |
dc.date | 2017-08-08 | - |
dc.date.accessioned | 2018-08-30T06:04:45Z | - |
dc.date.available | 2018-08-30T06:04:45Z | - |
dc.date.issued | 2018-03 | - |
dc.identifier.citation | Surgical endoscopy 2018; 32(3): 1600-1606 | - |
dc.identifier.uri | https://ahro.austin.org.au/austinjspui/handle/1/18462 | - |
dc.description.abstract | BACKGROUND: Laparoscopic lens fogging (LLF) hampers vision and impedes operative efficiency. Attempts to reduce LLF have led to the development of various anti-fogging fluids and warming devices. Limited literature exists directly comparing these techniques. We constructed a model peritoneum to simulate LLF and to compare the efficacy of various anti-fogging techniques. MATERIALS AND METHODS: Intraperitoneal space was simulated using a suction bag suspended within an 8 L container of water. LLF was induced by varying the temperature and humidity within the model peritoneum. Various anti-fogging techniques were assessed including scope warmers, FREDTM, ResoclearTM, chlorhexidine, betadine and immersion in heated saline. These products were trialled with and without the use of a disposable scope warmer. Vision scores were evaluated by the same investigator for all tests and rated according to a predetermined scale. Fogging was assessed for each product or technique 30 times and a mean vision rating was recorded. RESULTS: All products tested imparted some benefit, but FREDTM performed better than all other techniques. Betadine and ResoclearTM performed no better than the use of a scope warmer alone. Immersion in saline prior to insertion resulted in decreased vision ratings. The robotic scope did not result in LLF within the model. CONCLUSIONS: In standard laparoscopes, the most superior preventative measure was FREDTM utilised on a pre-warmed scope. Despite improvements in LLF with other products FREDTM was better than all other techniques. The robotic laparoscope performed superiorly regarding LLF compared to standard laparoscope. | - |
dc.language.iso | eng | - |
dc.subject | Fogging | - |
dc.subject | Laparoscopic equipment | - |
dc.subject | Laparoscopic lens fogging | - |
dc.subject | Laparoscopic surgery | - |
dc.subject | Robotic surgery | - |
dc.subject | Surgery | - |
dc.title | Laparoscopic lens fogging: solving a common surgical problem in standard and robotic laparoscopes via a scientific model | - |
dc.type | Journal Article | - |
dc.identifier.journaltitle | Surgical endoscopy | - |
dc.identifier.affiliation | Young Urology Researchers Organisation (YURO), Melbourne, Australia | en |
dc.identifier.affiliation | Olivia Newton-John Cancer Research Institute, Heidelberg, Victoria, Australia | en |
dc.identifier.affiliation | Department of Surgical Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia | en |
dc.identifier.affiliation | Department of Engineering (Chemical), University of Melbourne, Melbourne, Australia | en |
dc.identifier.doi | 10.1007/s00464-017-5772-x | - |
dc.identifier.orcid | 0000-0001-8553-5618 | en |
dc.identifier.orcid | 0000-0003-2951-3726 | en |
dc.identifier.orcid | 0000-0002-4140-1500 | en |
dc.identifier.orcid | 0000-0002-5145-6783 | en |
dc.identifier.orcid | 0000-0001-5609-3769 | en |
dc.identifier.orcid | 0000-0002-3188-1803 | en |
dc.identifier.orcid | 0000-0002-1138-6389 | en |
dc.identifier.pubmedid | 28791559 | - |
dc.type.austin | Journal Article | - |
local.name.researcher | Bolton, Damien M | |
item.openairetype | Journal Article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | Urology | - |
crisitem.author.dept | Surgery | - |
crisitem.author.dept | Urology | - |
crisitem.author.dept | Urology | - |
crisitem.author.dept | Urology | - |
Appears in Collections: | Journal articles |
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.