Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/17896
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKoshy, Anoop N-
dc.contributor.authorSajeev, Jithin K-
dc.contributor.authorNerlekar, Nitesh-
dc.contributor.authorBrown, Adam J-
dc.contributor.authorRajakariar, Kevin-
dc.contributor.authorZureik, Mark-
dc.contributor.authorWong, Michael C-
dc.contributor.authorRoberts, Louise-
dc.contributor.authorStreet, Maryann-
dc.contributor.authorCooke, Jennifer-
dc.contributor.authorTeh, Andrew W-
dc.date.accessioned2018-06-19T06:24:18Z-
dc.date.available2018-06-19T06:24:18Z-
dc.date.issued2018-09-01-
dc.identifier.citationInternational Journal of Cardiology 2018; 266: 124-127en_US
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/17896-
dc.description.abstractDespite studies demonstrating the accuracy of smart watches (SW) and wearable heart rate (HR) monitors in sinus rhythm, no data exists regarding their utility in arrhythmias. 102 hospitalized patients were evaluated at rest using continuous electrocardiogram (ECG) monitoring with concomitant SW-HR (FitBit, FB, Apple Watch, AW) for 30 min. Across all devices, 38,616 HR values were recorded. Sinus rhythm cohort demonstrated strong agreement for both devices with a low bias (FB & AW Bias = 1 beat). In atrial arrhythmias, AW demonstrated a stronger correlation than FB (AW rs = 0.83, FB rs = 0.56, both p < 0.01) with a lower bias (Bias AW = -5 beats, FB = -18 beats). Atrial flutter demonstrated strongest agreement in both devices with a mean bias <1 beat. However, in AF, there was significant HR underestimation (Bias FB = -28 beats, AW-8 beats) with wide limits of agreement. Despite HR underestimation in AF, when SW recorded HR ≥ 100 in arrhythmias, 98% of values were within ±10-beats of ECG-HR. SW demonstrate strong agreement for HR estimation in sinus rhythm and atrial flutter but underestimates HR in AF. Tachycardic episodes recorded at rest on a SW may be suggestive of an underlying atrial tachyarrhythmia and warrant further clinical evaluation. Australian New Zealand Clinical Trials Registry (www.anzctr.org.au) ACTRN: 12616001374459.en_US
dc.language.isoeng-
dc.subjectAccuracyen_US
dc.subjectArrhythmiasen_US
dc.subjectAtrial fibrillationen_US
dc.subjectHeart rateen_US
dc.subjectSmart watchen_US
dc.titleSmart watches for heart rate assessment in atrial arrhythmias.en_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleInternational Journal of Cardiologyen_US
dc.identifier.affiliationMonash University, Eastern Health Clinical School, Department of Cardiology, Box Hill Hospital, Victoria, Australiaen_US
dc.identifier.affiliationMonash Cardiovascular Research Centre, Department of Medicine, Monash University and Monash Heart, Monash Health, Clayton, Victoria, Australiaen_US
dc.identifier.affiliationDeakin University, Geelong, Victoria, Australiaen_US
dc.identifier.affiliationUniversity of Melbourne Clinical Schoolen_US
dc.identifier.affiliationCardiologyen_US
dc.identifier.doi10.1016/j.ijcard.2018.02.073en_US
dc.type.contentTexten_US
dc.identifier.pubmedid29887428-
dc.type.austinJournal Article-
local.name.researcherKoshy, Anoop N
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeJournal Article-
crisitem.author.deptCardiology-
crisitem.author.deptCardiology-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

10
checked on Mar 28, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.