dc.identifier.citation | Journal of Applied Clinical Medical Physics 2017; 18(6): 206-217 | en_US |
dc.identifier.uri | https://ahro.austin.org.au/austinjspui/handle/1/16906 | - |
dc.description.abstract | PURPOSE: This study investigates a large-area plane-parallel ionization chamber (LAC) for measurements of dose-area product in water (DAPw ) in megavoltage (MV) photon fields. METHODS: Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high-resolution microCT. Signal dependence on angle α of beam incidence for square 6 MV fields of side length s = 20 cm and 1 cm was measured in air. Polarity and recombination effects were characterized in 6, 10, and 18 MV photons fields. To assess the lateral setup tolerance, scanned LAC profiles of a 1 × 1 cm2 field were acquired. A 6 MV calibration coefficient, ND,w,LAC , was determined in a field collimated by a 5 cm diameter stereotactic cone with known DAPw . Additional calibrations in 10 × 10 cm2 fields at 6, 10, and 18 MV were performed. RESULTS: Electrode separation is uniform and agrees with specifications. Volume-averaging leads to a signal increase proportional to ~1/cos(α) in small fields. Correction factors for polarity and recombination range between 0.9986 to 0.9996 and 1.0007 to 1.0024, respectively. Off-axis displacement by up to 0.5 cm did not change the measured signal in a 1 × 1 cm2 field. ND,w,LAC was 163.7 mGy cm-2 nC-1 and differs by +3.0% from the coefficient derived in the 10 × 10 cm2 6 MV field. Response in 10 and 18 MV fields increased by 1.0% and 2.7% compared to 6 MV. CONCLUSIONS: The LAC requires only small correction factors for DAPw measurements and shows little energy dependence. Lateral setup errors of 0.5 cm are tolerated in 1 × 1 cm2 fields, but beam incidence must be kept as close to normal as possible. Calibration in 10 × 10 fields is not recommended because of the LAC's over-response. The accuracy of relative point-dose measurements in the field's periphery is an important limiting factor for the accuracy of DAPw measurements. | en_US |
dc.subject | dose-area product | en_US |
dc.subject | large-area chamber | en_US |
dc.subject | linear accelerators | en_US |
dc.subject | quality assurance | en_US |
dc.subject | small field dosimetry | en_US |
dc.title | Commissioning of a PTW 34070 large-area plane-parallel ionization chamber for small field megavoltage photon dosimetry | en_US |
dc.type | Journal Article | en_US |
dc.identifier.journaltitle | Journal of Applied Clinical Medical Physics | en_US |
dc.identifier.affiliation | School of Science, RMIT University, Melbourne, Victoria, Australia | en_US |
dc.identifier.affiliation | Radiation Oncology Centre, Austin Health, Heidelberg, Victoria, Australia | en_US |
dc.identifier.affiliation | Faculty of Science, The University of Sydney, Sydney, NSW, Australia | en_US |
dc.identifier.affiliation | Department of Radiation Oncology, Calvary Mater Newcastle, Waratah, NSW, Australia | en_US |
dc.identifier.affiliation | Australian Radiation Protection and Nuclear Safety Agency, Yallambie, Victoria, Australia | en_US |
dc.identifier.pubmeduri | https://pubmed.ncbi.nlm.nih.gov/28980432 | en_US |
dc.identifier.doi | 10.1002/acm2.12185 | en_US |
dc.type.content | Text | en_US |
dc.type.austin | Journal Article | en_US |
local.name.researcher | Kupfer, Tom | |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Journal Article | - |
crisitem.author.dept | Radiation Oncology | - |
Appears in Collections: | Journal articles |
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.