Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/16761
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKhor, Yet H-
dc.contributor.authorMcDonald, Christine F-
dc.contributor.authorHazard, Anita-
dc.contributor.authorSymons, Karen-
dc.contributor.authorWestall, Glen-
dc.contributor.authorGlaspole, Ian-
dc.contributor.authorGoh, Nicole SL-
dc.contributor.authorHolland, Anne E-
dc.date2017-05-23-
dc.date.accessioned2017-08-02T05:42:43Z-
dc.date.available2017-08-02T05:42:43Z-
dc.date.issued2017-11-
dc.identifier.citationRespirology 2017; 22(8): 1598-1603en_US
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/16761-
dc.description.abstractBACKGROUND AND OBJECTIVE: Ambulatory oxygen therapy is often provided to patients with interstitial lung disease (ILD). Lightweight portable oxygen concentrators (POCs) provide an alternative to traditional portable systems such as compressed oxygen cylinders; however, their efficacy in patients with ILD has not been assessed. This study aimed to evaluate the clinical performance of three ambulatory oxygen systems (two different POCs and a compressed oxygen cylinder) during 6-min walk tests (6MWTs) in patients with ILD and exertional desaturation. METHODS: A total of 20 participants with ILD of varying aetiologies who demonstrated exertional desaturation to <90% on room air during 6MWT were recruited. Each participant performed two 6MWTs while breathing room air. On a subsequent day, two further 6MWTs were performed, in random order: one breathing oxygen via a POC (either the Inogen One G2 POC or the EverGo POC at the setting of 6) and one with a compressed oxygen cylinder (at 5 L/min). RESULTS: There were no significant differences in nadir oxygen saturation (SpO2 ) during 6MWTs using different portable oxygen devices (Trial 1: mean SpO2 for Inogen One G2 POC: 82.3 ± 3.5% vs oxygen cylinder: 80.3 ± 2.2%, P = 0.14; Trial 2: mean SpO2 for EverGo POC: 85.7 ± 7.7% vs oxygen cylinder: 86.1 ± 6.1%, P = 0.79). The mean 6-min walk distances were not significantly different among the three devices. CONCLUSION: The performance of the Inogen One G2 POC and the EverGo POC had comparable performance with that of the compressed oxygen cylinder during walking in patients with ILD and exertional desaturation.en_US
dc.subjectExerciseen_US
dc.subjectExertional desaturationen_US
dc.subjectHypoxaemiaen_US
dc.subjectInterstitial lung diseaseen_US
dc.subjectOxygen therapyen_US
dc.subjectPulmonary fibrosisen_US
dc.titlePortable oxygen concentrators versus oxygen cylinder during walking in interstitial lung disease: A randomized crossover trialen_US
dc.typeJournal Articleen_US
dc.identifier.journaltitleRespirologyen_US
dc.identifier.affiliationRespiratory and Sleep Medicineen_US
dc.identifier.affiliationInstitute for Breathing and Sleepen_US
dc.identifier.affiliationDepartment of Allergy, Immunology and Respiratory Medicine, Alfred Health, Melbourne, Victoria, Australiaen_US
dc.identifier.affiliationDepartment of Physiotherapy, La Trobe University/Alfred Health, Melbourne, Victoria, Australiaen_US
dc.identifier.pubmedurihttps://pubmed.ncbi.nlm.nih.gov/28544460en_US
dc.identifier.doi10.1111/resp.13083en_US
dc.type.contentTexten_US
dc.identifier.orcid0000-0002-5434-9342en_US
dc.identifier.orcid0000-0002-5118-2890en_US
dc.identifier.orcid0000-0003-2061-845Xen_US
dc.type.austinJournal Articleen_US
local.name.researcherHolland, Anne E
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeJournal Article-
crisitem.author.deptRespiratory and Sleep Medicine-
crisitem.author.deptInstitute for Breathing and Sleep-
crisitem.author.deptMedicine (University of Melbourne)-
crisitem.author.deptInstitute for Breathing and Sleep-
crisitem.author.deptRespiratory and Sleep Medicine-
crisitem.author.deptInstitute for Breathing and Sleep-
crisitem.author.deptPhysiotherapy-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

38
checked on Dec 22, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.