Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/16058
Title: Thin section magnetic resonance diffusion-weighted imaging in the detection of acute infratentorial stroke
Austin Authors: Entwisle, Tom;Perchyonok, Yuliya ;Fitt,Gregory J 
Affiliation: Department of Radiology, Austin Health, Heidelberg, Victoria, Australia
Issue Date: Oct-2016
Date: 2016-06-21
Publication information: Journal of Medical Imaging and Radiation Oncology 2016; 60(5): 616-623
Abstract: INTRODUCTION: Magnetic resonance diffusion-weighted imaging (DWI) is the most accurate technique available for demonstrating acute infarction; however, false-negative DWI is higher in the infratentorium due to the limited spatial resolution with conventional 5 mm DWI. The aim of this study was to compare 5 mm DWI with 3 mm DWI in the detection of acute infratentorial infarction. METHODS: A 3 mm DWI sequence of the infratentorium was incorporated into the conventional MRI stroke protocol for the evaluation of patients with vertebrobasilar stroke-like deficits. The 5 mm and 3 mm DWI sequences were assessed by two neuroradiologists who were blinded to the clinical findings. Sensitivity and specificity analysis was then performed against the final clinical diagnosis. RESULTS: The sensitivity for detection of infratentorial infarction was 81.1% for 5 mm DWI and 94.6% for 3 mm DWI and the specificity was 100% for 5 mm DWI and 97.7% for 3-mm DWI. The false-negative rate in detection of infratentorial infarcts was 5.6% for the 5-mm sequence and 1.6% for the 3-mm sequence. The six 5-mm DWI false-negative cases (4.8%) were less than 9 mm in diameter (3-8 mm, average 4.67 mm) and located in the brainstem. This supports the hypothesis that small lesions may not be detected on 5 mm DWI due to partial volume averaging. CONCLUSION: Where there is clinical suspicion of infratentorial infarction, 3 mm DWI of the infratentorium adds sensitivity compared to 5 mm DWI with only a small reduction in specificity.
URI: https://ahro.austin.org.au/austinjspui/handle/1/16058
DOI: 10.1111/1754-9485.12490
ORCID: 0000-0002-2903-4605
Journal: Journal of Medical Imaging and Radiation Oncology
PubMed URL: https://pubmed.ncbi.nlm.nih.gov/27324575
Type: Journal Article
Subjects: diffusion-weighted Magnetic Resonance Imaging
infratentorial infarction
Appears in Collections:Journal articles

Show full item record

Page view(s)

46
checked on Dec 27, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.