dc.identifier.citationCritical Care and Resuscitation; 17(1): 51-4en
dc.identifier.govdoc25702763en
dc.identifier.otherPUBMEDen
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/12649en
dc.description.abstractAutomated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function.Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis.We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout.Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.en
dc.language.isoenen
dc.subject.otherAutomationen
dc.subject.otherDatabases as Topicen
dc.subject.otherElectronics, Medicalen
dc.subject.otherEquipment Failureen
dc.subject.otherHumansen
dc.subject.otherPressureen
dc.subject.otherRenal Replacement Therapyen
dc.titleAutomated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.en
dc.typeJournal Articleen
dc.identifier.journaltitleCritical Care and Resuscitationen
dc.identifier.affiliationDepartment of Intensive Care, Austin Health, Heidelberg, Victoria, Australiaen
dc.description.pages51-4en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/25702763en
dc.type.austinJournal Articleen
local.name.researcherBaldwin, Ian C
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
crisitem.author.deptIntensive Care-
crisitem.author.deptIntensive Care-
crisitem.author.deptData Analytics Research and Evaluation (DARE) Centre-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

50
checked on Nov 28, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.