Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/11875
Title: Determination of the appropriate b value and number of gradient directions for high-angular-resolution diffusion-weighted imaging.
Austin Authors: Tournier, Jacques-Donald;Calamante, Fernando;Connelly, Alan
Affiliation: The Florey Institute of Neuroscience and Mental Health, Melbourne, Victoria, Australia
Department of Medicine, Austin Health and Northern Health, University of Melbourne, Melbourne, Victoria, Australia
Issue Date: 29-Aug-2013
Publication information: Nmr in Biomedicine 2013; 26(12): 1775-86
Abstract: High-angular-resolution diffusion-weighted imaging (HARDI) is one of the most common MRI acquisition schemes for use with higher order models of diffusion. However, the optimal b value and number of diffusion-weighted (DW) directions for HARDI are still undetermined, primarily as a result of the large number of available reconstruction methods and corresponding parameters, making it impossible to identify a single criterion by which to assess performance. In this study, we estimate the minimum number of DW directions and optimal b values required for HARDI by focusing on the angular frequency content of the DW signal itself. The spherical harmonic (SH) series provides the spherical analogue of the Fourier series, and can hence be used to examine the angular frequency content of the DW signal. Using high-quality data acquired along 500 directions over a range of b values, we estimate that SH terms above l = 8 are negligible in practice for b values up to 5000 s/mm(2), implying that a minimum of 45 DW directions is sufficient to fully characterise the DW signal. l > 0 SH terms were found to increase as a function of b value, levelling off at b = 3000 s/mm(2), suggesting that this value already provides the highest achievable angular resolution. In practice, it is recommended to acquire more than the minimum of 45 DW directions to avoid issues with imperfections in the uniformity of the DW gradient directions and to meet signal-to-noise requirements of the intended reconstruction method.
Gov't Doc #: 24038308
URI: http://ahro.austin.org.au/austinjspui/handle/1/11875
DOI: 10.1002/nbm.3017
Journal: NMR in biomedicine
URL: https://pubmed.ncbi.nlm.nih.gov/24038308
Type: Journal Article
Subjects: HARDI
diffusion-weighted MRI
high-angular-resolution diffusion-weighted MRI
Algorithms
Computer Simulation
Diffusion Magnetic Resonance Imaging
Humans
Signal-To-Noise Ratio
Appears in Collections:Journal articles

Show full item record

Page view(s)

6
checked on Mar 30, 2023

Google ScholarTM

Check