dc.description.abstract | The ultrasonic cardiac output monitor is a non-invasive, continuous-wave Doppler monitor that can be used to measure cardiac output. Its accuracy and precision in peri-operative and critical care has been assessed with varied results. We conducted a meta-analysis to calculate a pooled mean bias, precision and percentage error for this device. Six studies were suitable for inclusion into a pooled parametric analysis consisting of 320 measurements. The mean weighted bias was -0.39 l.min(-1) (95% CI -0.25 to -0.53 l.min(-1) ), precision 1.27 l.min(-1) and percentage error 42.7% (95% CI 38.5-46.9%). The ultrasonic cardiac output monitor achieved similar agreement with bolus thermodilution to that of other minimally invasive methods of peri-operative cardiac output monitoring, and may have a useful role in cardiac output monitoring. | en |
dc.language.iso | en | en |
dc.subject.other | Cardiac Output | en |
dc.subject.other | Echocardiography, Doppler | en |
dc.subject.other | Humans | en |
dc.subject.other | Monitoring, Intraoperative.methods | en |
dc.subject.other | Reproducibility of Results | en |
dc.subject.other | Thermodilution | en |
dc.title | A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM). | en |
dc.type | Journal Article | en |
dc.identifier.journaltitle | Anaesthesia | en |
dc.identifier.affiliation | Department of Anaesthesia, Austin Hospital, Melbourne, Australia | en |
dc.identifier.doi | 10.1111/j.1365-2044.2012.07311.x | en |
dc.description.pages | 1266-71 | en |
dc.relation.url | https://pubmed.ncbi.nlm.nih.gov/22928650 | en |
dc.type.austin | Journal Article | en |
local.name.researcher | Peyton, Philip J | |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairetype | Journal Article | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | Anaesthesia | - |
crisitem.author.dept | Institute for Breathing and Sleep | - |
Appears in Collections: | Journal articles |
Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.