Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/10315
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGong, Sylvia Jen
dc.contributor.authorO'keefe, Graeme Jen
dc.contributor.authorScott, Andrew Men
dc.date.accessioned2015-05-15T23:43:49Z
dc.date.available2015-05-15T23:43:49Z
dc.date.issued2005en
dc.identifier.citationConference Proceedings : ... Annual International Conference of the Ieee Engineering in Medicine and Biology Society. Ieee Engineering in Medicine and Biology Society. Annual Conference; 2(): 1599-603en
dc.identifier.govdoc17282512en
dc.identifier.otherPUBMEDen
dc.identifier.urihttps://ahro.austin.org.au/austinjspui/handle/1/10315en
dc.description.abstractDiagnosis, treatment planning and prognosis may be improved by combining functional data with anatomic location via PET/CT dual-modality image registration. The aim of this work is to reveal the spatial accuracy, reliability and speed of registration techniques used in GeminiTM PET/CT Imaging System, as a part of quality assurance program for clinical and research applications. A multi-layer alignment bearing source device was used to validate PET/CT intrinsic alignment, as well as a Rando a Man phantom. A series of known transformations were performed to simulate different misalignment between PET and CT images. Two semi-automated registration techniques used to correct misalignment were assessed and compared quantitatively by measuring absolute distances between the centroids of corresponding fiducial markers in the registered volumes. Comparisons between independent and cross fiducial localization indicate that fused PET/CT is superior to visual correlation of PET and CT individually in identifying registration errors. The experimental and theoretical findings confirm that PET/CT hybrid system can produce robust intrinsic image alignment and accurate PET/CT image registration with careful user interaction. The maximum spatial error in our experiments is below 4 mm, and is better than the spatial resolution of the PET scanner used. This is considered to be sufficient for most PET/CT applications.en
dc.language.isoenen
dc.titleComparison and Evaluation of PET/CT Image Registration.en
dc.typeJournal Articleen
dc.identifier.journaltitleConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conferenceen
dc.identifier.affiliationMember, IEEE, Centre for PET, Austin Hospital, Melbourne, VIC 3084, Australiaen
dc.identifier.doi10.1109/IEMBS.2005.1616743en
dc.description.pages1599-603en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/17282512en
dc.type.austinJournal Articleen
local.name.researcherScott, Andrew M
item.openairetypeJournal Article-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
crisitem.author.deptMolecular Imaging and Therapy-
crisitem.author.deptOlivia Newton-John Cancer Research Institute-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

20
checked on Nov 26, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.