Austin Health

Title
A Pilot and Feasibility Study of Continuous Cardiac Output and Blood Pressure Monitoring during Intermittent Hemodialysis.
Publication Date
2024
Author(s)
Spano, Sofia
Maeda, Akinori
Lam, Joey
Chaba, Anis
Phongphithakchai, Atthaphong
Pattamin, Nuttapol
Hikasa, Yukiko
See, Emily J
Mount, Peter F
Bellomo, Rinaldo
Subject
Cardiac output
Cardiovascular physiology
End-stage kidney disease
Hemodynamics
Intermittent hemodialysis
Type of document
Journal Article
OrcId
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
#PLACEHOLDER_PARENT_METADATA_VALUE#
DOI
10.1159/000541201
Abstract
Hypotension is common during intermittent hemodialysis (IHD) and may be due to a decreased cardiac index (CI). However, no study has simultaneously and continuously measured CI and mean arterial pressure (MAP) to understand the prevalence, severity, and duration of CI decreases or relate them to MAP, blood volume (BV), and net ultrafiltration (NUF) rate. In a prospective, pilot and feasibility investigation, we studied 10 chronic IHD patients. We used the ClearSight System™ to continuously monitor CI and MAP; the CRIT-LINE®IV monitor to detect BV changes and collected data on NUF rate. Device tolerance and compliance were 100%. All patients experienced at least ≥1 episode of severe CI decrease (>25% from baseline), with a median duration of 24 min (IQR 6-87) and of 68 min [14-106] for moderate decreases (>15% but ≤25% from baseline). Eight patients experienced a low CI state (<2.2 L/min/m2). The lowest CI was 0.9 L/min/m2 with a concomitant MAP of 94 mm Hg. When the fall in CI was severe, MAP increased in 58% of cases and remained stable in 28%. Overall, CI decreased by -0.55 L/min/m2 when BV decrease was moderate versus mild (p < 0.001) and by -0.8 L/min/m2 when NUF rate was high versus low (p < 0.001). Continuous CI monitoring is feasible in IHD and shows frequent moderate-severe CI decreases, sometimes to low CI state levels. Such decreases are typically associated with markers of decreased intravascular volume status but not with a decrease in MAP, implying marked vasoconstriction.
Link
Citation
Blood Purification 2024; 53(11-12)
Jornal Title
Blood Purification
ISSN
1421-9735

Files: