Please use this identifier to cite or link to this item: https://ahro.austin.org.au/austinjspui/handle/1/12105
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWong, Benjamin Ten
dc.contributor.authorGlassford, Neil Jen
dc.contributor.authorBion, Victoriaen
dc.contributor.authorChai, Syn Yen
dc.contributor.authorBellomo, Rinaldoen
dc.date.accessioned2015-05-16T01:45:11Z-
dc.date.available2015-05-16T01:45:11Z-
dc.date.issued2014-03-01en
dc.identifier.citationCritical Care and Resuscitation; 16(1): 73-5en
dc.identifier.govdoc24588440en
dc.identifier.otherPUBMEDen
dc.identifier.urihttp://ahro.austin.org.au/austinjspui/handle/1/12105en
dc.description.abstractBlood pressure management (assessed using nursing charts) in the early phase of septic shock may have an effect on renal outcomes. Assessment of mean arterial pressure (MAP) values as recorded on nursing charts may be inaccurate.To determine the difference between hourly blood pressure values as recorded on the nursing charts and hourly average blood pressure values over the corresponding period obtained electronically from the bedside monitor.We studied 20 patients with shock requiring vasopressor support and invasive blood pressure monitoring. Hourly blood pressure measurements were recorded on the nursing charts over a 12-hour period. Blood pressure values recorded every 10 minutes were downloaded from electronic patient monitors over the corresponding period. The hourly average of the 10-minute blood pressure values was compared with the measurements recorded on the nursing charts.We assessed 240 chart readings and 1440 electronic recordings. Average chart MAP was 72.54 mmHg and average electronic monitor MAP was 71.54 mmHg. MAP data from the two sources showed a strong correlation (ρ0.71, P < 0.005). Bland-Altman assessment revealed acceptable agreement, with a mean bias of 1mmHg and 95% limits of agreement of -11.76 mmHg and 13.76 mmHg. Using average data over 6 hours, 95% limits of agreement narrowed to -6.79mmHg and 8.79mmHg.With multiple measurements over time, mean blood pressure as recorded on nursing charts reasonably approximates mean blood pressure recorded on the monitor.en
dc.language.isoenen
dc.subject.otherBlood Pressure.physiologyen
dc.subject.otherBlood Pressure Determination.instrumentation.nursingen
dc.subject.otherEquipment Designen
dc.subject.otherHumansen
dc.subject.otherMonitoring, Physiologic.instrumentation.nursingen
dc.subject.otherNursing Recordsen
dc.subject.otherROC Curveen
dc.subject.otherReproducibility of Resultsen
dc.subject.otherShock, Septic.physiopathologyen
dc.titleInvasive blood pressure recording comparing nursing charts with an electronic monitor: a technical report.en
dc.typeJournal Articleen
dc.identifier.journaltitleCritical Care and Resuscitationen
dc.identifier.affiliationDepartment of Intensive Care, Austin Health, Heidelberg, Victoria, Australiaen
dc.description.pages73-5en
dc.relation.urlhttps://pubmed.ncbi.nlm.nih.gov/24588440en
dc.type.austinJournal Articleen
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeJournal Article-
crisitem.author.deptIntensive Care-
crisitem.author.deptData Analytics Research and Evaluation (DARE) Centre-
Appears in Collections:Journal articles
Show simple item record

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.