dc.description.abstractCystic fibrosis (CF) predominantly affects young adults. Accurate radiological assessment of pulmonary disease is vital for predicting exacerbations, one of the leading causes of morbidity and mortality. We evaluated the image quality of model-based iterative reconstruction (MBIR) ultra-low-dose CT chest (ULD-CT) in CF evaluation. We compared ULD-CT with standard adaptive statistical iterative reconstruction (ASIR) low-dose CT (LD-CT). Subjective assessment of contrast and noise were performed for each study. Background noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated and compared between the CT studies. Conspicuity of major structures was assessed. These aspects of image quality were compared to determine whether ULD-CT was superior to LD-CT in assessment of CF. The ULD-CT achieved median effective dose of 0.073 mSv, comparable to one standard chest radiograph and significantly lower than the median LD-CT dose of 1.22 mSv. ULD-CT had lower subjective contrast and higher subjective noise when compared to LD-CT. Objectively measured background noise was lower in ULD-CT (16.33 HU vs 38.53 HU, P < 0.0001) compared to LD-CT. ULD-CT had higher median CNR (52.65 vs 22.09, P < 0.0001) and SNR in lung (9.08 vs 7.29, P = 0.002) compared to LD-CT. ULD-CT was equal to LD-CT in identification of trachea, bronchi, pleural and pericardium. Interobserver reliability showed agreement of 80-92%. The image quality of ULD-CT is similar to LD-CT, at 1/16th the dose. MBIR constructed ULD-CT is an effective imaging modality for CF surveillance, with potential applications in other disease settings.-
dc.language.isoeng-
dc.subjectCT-
dc.subjectMBIR-
dc.subjectchest-
dc.subjectcystic fibrosis-
dc.subjectultra-low dose-
dc.titleImage quality comparison between model-based iterative reconstruction and adaptive statistical iterative reconstruction chest computed tomography in cystic fibrosis patients.-
dc.typeJournal Article-
dc.identifier.journaltitleJournal of Medical Imaging and Radiation Oncology-
dc.identifier.affiliationFaculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australiaen
dc.identifier.affiliationAustin Health, Heidelberg, Victoria, Australiaen
dc.identifier.affiliationDepartment of Diagnostic Imaging, Monash Health, Melbourne, Victoria, Australiaen
dc.identifier.doi10.1111/1754-9485.12895-
dc.identifier.orcid0000-0001-8959-1828-
dc.identifier.pubmedid31090256-
dc.type.austinJournal Article-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairetypeJournal Article-
Appears in Collections:Journal articles
Show simple item record

Page view(s)

8
checked on Mar 28, 2024

Google ScholarTM

Check


Items in AHRO are protected by copyright, with all rights reserved, unless otherwise indicated.